Heading 84.14
EU TARICAir or vacuum pumps, air or other gas compressors and fans; ventilating or recycling hoods incorporating a fan, whether or not fitted with filters; gas-tight biological safety cabinets, whether or not fitted with filters; parts thereof
10 subheadings · 71 TARIC codes
8414.10Vacuum pumps8 codes
Code / DescriptionThird-Country Duty
8414.10.15.00Of a kind used for the manufacture of semiconductors or solely or principally used for the manufacture of flat panel displays
0.00 %8414.10.25.10For use in civil aircraft
—8414.10.25.30Tandem pump consisting of: -an oil pump with displacement of 21,6 cc/rev (± 2 cc/rev) and working pressure 1,5 bar at 1 000 revolutions per minute, -vacuum pump with displacement of 120 cc/rev (± 12 cc/rev) and performance of -666 mbar in 6 seconds at 750 revolutions per minute for use in the manufacture of engines of motor vehicles
1.70 %8414.10.25.90Other
1.70 %8414.10.81.10For use in civil aircraft
—8414.10.81.90Other
1.70 %8414.10.89.10For use in civil aircraft
—8414.10.89.90Other
1.70 %Code / DescriptionThird-Country Duty
8414.20.20.00Handpumps for cycles
1.70 %8414.20.80.10For use in civil aircraft
—8414.20.80.90Other
2.20 %Code / DescriptionThird-Country Duty
8414.30.20.10For use in civil aircraft
—8414.30.20.90Other
2.20 %8414.30.81.10For use in civil aircraft
—8414.30.81.50Hermetic or semi-hermetic variable-speed electric scroll compressors, with a nominal power rating of 0,5 kW or more but not more than 10 kW, with a displacement volume of not more than 35 cm³, of the type used in refrigeration equipment
2.20 %8414.30.81.60Hermetic rotary compressors for either hydrofluorocarbon (HFC) or hydrocarbon refrigerants: - driven by ‘on-off’ single phase alternate current (AC) or ‘brushless direct current’ (BLDC) variable speed motors, - with a nominal power rating of not more than 1,5kW, - a rated voltage of 100V or more but not more than 240V, - with a height of not more than 300mm, - an external diameter of not more than 150mm, - with a unit weight of not more than 15kg, for use in the manufacture of heat pumps for household appliances, including clothes dryers
2.20 %8414.30.81.89Other
2.20 %8414.30.89.10For use in civil aircraft
—8414.30.89.20Vehicle air conditioning system part, consisting of an open shaft reciprocating compressor of a power of more than 0,4|kW but not more than 10|kW
2.20 %8414.30.89.40Electrical compressor for motor vehicle air conditioning system:
-with a power output of more than 0,4 kW but not exceeding 10 kW,
for use in the manufacture of motor vehicles of subheading 8703 40
2.20 %8414.30.89.90Other
2.20 %Code / DescriptionThird-Country Duty
8414.40.10.00Giving a flow per minute not exceeding 2|m$3
2.20 %8414.40.90.00Giving a flow per minute exceeding 2|m$3
2.20 %8414.59Blowers for pipe organs12 codes
Code / DescriptionThird-Country Duty
8414.59.15.00Fans of a kind used solely or principally for cooling microprocessors, telecommunication apparatus, automatic data processing machines or units of automatic data processing machines
0.00 %8414.59.25.10For use in civil aircraft
—8414.59.25.50Axial fans with built-in motor, for the generation of an air flow for the cooling of compressors and the distribution of air with
-a direct current operating voltage of more than 10 V but not more than 14 V, or
-an alternating current operating voltage of more than 185 V, but not more than 254 V,
-an operating temperature of -40 °C or higher, but not higher than 70 °C,
for use in the manufacture of heat pump tumble dryers and refrigerators or freezers
2.30 %8414.59.25.60Axial Fan, for incorporation into instrument clusters, speedometers and infotainment systems of transport vehicles as motor vehicles of headings 8701 to 8705, with:
-an air flow of not more than 0,75 m3/min (cubic meter per minute)
-an air pressure of not more than 10 mmH2O
-an overall acoustic noise of not more than 45 dB(A)
-a diameter of not more than 65mm
Equipped with DC Brushless motor with:
-a rated voltage between: 3 to 16 VDC
-an operating voltage between: 3 to 16 VDC
-a rated current between: 0,03 to 0,30 A
-an input power between: 0,3 to 1,5 W
-a rotation speed between: 2500 to 10000 R.P.M,
With or without a heat sink incorporated
2.30 %8414.59.25.90Other
2.30 %8414.59.35.10For use in civil aircraft
—8414.59.35.20Radial fan, with: -a dimension of 25mm (height) x 85mm (width) x 85mm (depth), -a weight of 120 g, -a rated voltage of 13,6 VDC (direct current voltage), -an operating voltage of 9 VDC or more but not more than 16 VDC (direct current voltage), -a rated current of 1,1 A (TYP), -a rated power of 15 W, -a rotation speed of 500 RPM (revolutions per minute) or more but not more than 4800 RPM (revolutions per minute) (free flow), -an air flow of not more than 17,5 litre/s, -an air pressure of not more than16 mm H2O ≈ 157 Pa, -an overall sound pressure of not more than 58 dB(A) at 4800 RPM (revolutions per minute), and with a FIN (Fan Interconnect Network) interface for communication with the heating and air-conditioning control unit used in car seat ventilation systems
2.30 %8414.59.35.30Electric blower for cooling the high-voltage battery of a hybrid passenger car with: -a control unit, -MOSFET inverter, -a voltage of 9 V or more but not more than 16 V, -ambient temperature of - 40 °C or more, but not more than 80 °C, for use in the manufacture of hybrid passenger cars
2.30 %8414.59.35.40Electric blower for cooling the battery module:
-with an operating voltage of 9 VDC or more but not more than 16 VDC,
-with a centrifugal electric fan,
-with a connector,
-with a plastic case,
-with or without a control unit for the fan electric motor,
for use in the production of rechargeable batteries for hybrid and electric vehicles
2.30 %8414.59.35.90Other
2.30 %8414.59.95.10For use in civil aircraft
—8414.59.95.90Other
2.30 %Code / DescriptionThird-Country Duty
8414.60.00.00Hoods having a maximum horizontal side not exceeding 120|cm
2.70 %Code / DescriptionThird-Country Duty
8414.70.00.00Gas-tight biological safety cabinets
2.20 %Code / DescriptionThird-Country Duty
8414.80.11.10For use in civil aircraft
—8414.80.11.90Other
2.20 %8414.80.19.10For use in civil aircraft
—8414.80.19.90Other
2.20 %8414.80.22.10For use in civil aircraft
—8414.80.22.20Air membrane compressor with: -|a flow of 4,5|l/min or more, but not more than 12|l/min, -|power input of not more than 14|W, and -|a gauge pressure capacity not exceeding 400|hPa (0,4|bar) of a kind used in the production of motor vehicle seats
2.20 %8414.80.22.90Other
2.20 %8414.80.28.10For use in civil aircraft
—8414.80.28.90Other
2.20 %8414.80.51.10For use in civil aircraft
—8414.80.51.90Other
2.20 %8414.80.59.10For use in civil aircraft
—8414.80.59.90Other
2.20 %8414.80.73.10For use in civil aircraft
—8414.80.73.30Hermetic rotary compressors for either hydrofluorocarbon (HFC) or hydrocarbon refrigerants: - driven by ‘on-off’ single phase alternate current (AC) or ‘brushless direct current’ (BLDC) variable speed motors, - with a nominal power rating of not more than 1,5kW, - a rated voltage of 100V or more but not more than 240V, - with a height of not more than 300mm, - an external diameter of not more than 150mm, - with a unit weight of not more than 15kg, for use in the manufacture of heat pumps for household appliances, including clothes dryers
2.20 %8414.80.73.50Hermetic heat pump compressor for R450A or R290 refrigerants:
- not charged with refrigerant,
- pre-charged with lubricant oil,
- with a single phase induction permanent split capacitor motor or a DC brushless motor,
- having suction and/or discharge connections,
- with a displacement of 8,05 cm3 or more, but not more than 55 cm3,
- running at 900 rpm or more, but not more than 7 800 rpm, and
- with a cooling capacity of 920 W or more, but not more than 10 440 W in ASHRAE conditions
2.20 %8414.80.73.89Other
2.20 %8414.80.75.10For use in civil aircraft
—8414.80.75.90Other
2.20 %8414.80.78.10For use in civil aircraft
—8414.80.78.90Other
2.20 %8414.80.80.10For use in civil aircraft
—8414.80.80.90Other
2.20 %Code / DescriptionThird-Country Duty
8414.90.00.10For use in civil aircraft
—8414.90.00.15Fan assembly made of aluminium and magnesium alloy:
-with an outer diameter of 54 mm or more but not more than 130 mm,
-with a height of 8 mm or more but not more than 30 mm,
-with two discs connected by blades of involute shape,
-with or without dowel, and with or without washer,
for use in the manufacture of electromotors
2.20 %8414.90.00.20Aluminium pistons, for incorporation into compressors of air conditioning machines of motor vehicles
2.20 %8414.90.00.25Scroll type compressor housing of an aluminium alloy of a kind with:
-a heat resistance of 200 °C or more but not more than 250 °C,
-one or more fixing points suitable for mounting an actuator,
for use in the manufacture of turbochargers
2.20 %8414.90.00.35Compressor head unit made of impregnated aluminium alloy for installation in air-conditioning compressors for motor vehicles with:
-a width of 115 mm or more but not more than 160 mm,
-a length of 115 mm or more but not more than 170 mm,
-a height of 30 mm or more but not more than 100 mm,
-a piece of pressure branch with pipe connection,
-one or two mounting holes and
-more than one overflowing hole
2.20 %8414.90.00.45Pressure casted rotor front plate or cover of an electric supercharger:
-of EN AC-46000 aluminium,
-shot-blasted and machined,
-with a hardness of 60 or more on the Hardness Brinell Wolfram (HBW) scale (2,5/62,5, according to ISO 6506),
-with a tensile strength of 240 N/mm2 or more,
-with a height of 22 mm or more but not more than 26 mm,
-with a diameter of 128 mm or more but not more than 136 mm,
-with a weight of 220 g or more but not more than 250 g
2.20 %8414.90.00.55Air conditioning compressor housing component made of aluminum alloy for installation in electric air conditioning compressors for motor vehicles:
-with a width of 100 mm or more but not more than 220 mm,
-with a length of 100 mm or more but not more than 230 mm,
-with a height of 80 mm or more but not more than 180 mm,
-with one single central bore,
-machined by CNC milling or unwrought,
-whether or not impregnated,
-with one suction port or without
2.20 %8414.90.00.80Turbocharger wheel housing of cast aluminium alloy or cast iron: - with a heat resistance up to 400°C, - with a hole of 30 mm or more but not more than 300 mm for the insertion of the compressor wheel, for use in the automotive industry
2.20 %8414.90.00.90Other
2.20 %Source: EU TARIC database (European Commission). For informational purposes only. Consult the official TARIC and a licensed customs broker for binding rates.